Technology

Engineering the
Science of Dry

How It Works

Three Steps to Dry Air

01
01

Humid Air Intake

Ambient air containing moisture is drawn into the unit via variable-speed fans. Pre-filters remove particulates before the airstream enters the desiccant rotor section, ensuring long-term rotor performance.

Humid Air Intake
02
02

Desiccant Wheel Absorption

The process air passes through a slowly rotating desiccant wheel coated in silica gel or lithium chloride. Moisture molecules are adsorbed directly onto the desiccant matrix. A separate regeneration air stream — heated to 100-140°C — continuously reactivates the saturated desiccant, expelling the absorbed moisture to the outside.

Desiccant Wheel Absorption
03
03

Dry Air Delivery

The now-dry process air exits the unit at the target humidity set point — reliably delivering between 1% and 50% RH depending on the application. CONSORB and RECUSORB units can be ducted directly into the protected environment or used as standalone climate control units.

Dry Air Delivery

Core Technologies

What Sets ClimaCore Apart

⚙️

Desiccant Rotor

The core of every ClimaCore system: a slowly rotating silica gel or molecular sieve wheel that continuously adsorbs and desorbs moisture without wear or degradation.

♻️

Energy Recovery

Integrated heat exchangers reclaim up to 80% of the energy used in desiccant regeneration, dramatically reducing operating costs in large-scale installations.

📡

Smart Controls

IoT-connected humidity sensors and BMS integration allow real-time remote monitoring, predictive maintenance alerts, and automated set-point adjustment.

🌿

VOC Adsorption

Specialist desiccant matrices can simultaneously capture volatile organic compounds alongside moisture — ideal for pharmaceutical and cleanroom environments.

Performance

Engineered for Extreme Conditions

ClimaCore systems are validated to perform where conventional refrigerant-based dehumidifiers fail — in sub-zero environments, high-altitude facilities, and around-the-clock industrial processes.

All performance figures are verified under EN 13779 test conditions. Contact us for site-specific performance data.

Temperature Range -30°C to 55°C
Humidity Range 1% to 95% RH
Energy Efficiency (COP) Up to 4.5
Max Airflow 50,000 m³/h

Quality & Compliance

Certifications & Standards

Every ClimaCore system is designed, manufactured, and tested to the highest international standards.

ISO 9001:2015
CE Mark
UL Listed
ATEX Zone 1 & 2
Energy Star
EN 13779

Want to Know More?

Download our technology white paper or speak with one of our engineers about your specific requirements.

Download White Paper Talk to an Engineer